RMS200184 Hotfix Upgrade Package for Managed Device and Distribution Server

Affected Versions: RMS 10.5.1

Type: Hotfix

ID: RMS-1858, RMS-1879, RMS-1922

 

Issues:

RMS-1858:

The package installation was not working correctly. Files even when having the same version and checksum were replaced. This caused a reboot in case the file was in use. Now the comparison check works correctly and the unneeded replacement is not anymore performed.

RMS-1879:

In case the package was not anymore allocated to the managed device, it used to be not possible to call the verify functionality in the selector. After pressing the 'Verify' button, nothing was happening.

The condition got adjusted, so that even not allocated but rather installed packages can be repaired using the 'Verify' button

RMS-1922:
The processes were running in user context for events from machine schedule. Calling mechanism has been fixed to resolve this issue.

 

WARNING:

Known issue: Do not use this hotfix if the IMPORTER feature is active on your DS. Import of inventory will not work. Use #6703 instead. You will find this Hofix on our FTP under "10.5.1 --> HotFixes --> #6703"

 

Attachment:

You will find the HotFix on our FTP under "10.5.1 --> HotFixes --> #6751"

FTP Server: ftp://ftp.raynet.de or https://ftp.raynet.de/login.html
User: FTP4RMS
Password: pwd4rms106

 

 